Pharmaceutical Flow Meter Application for Batching

In: Flow Meter Application

1 Apr 2009

Company Type: Medical Device Manufacturing

Market: Pharmaceuticals

Application Category: Batching

GPI Flow Meters Used: GNT-051 with GX500

 

Problem:

The manufacturing process required accurate measurement of two materials into a single batch. Two lines supply materials that are batched into a blend tank.

Flow Meter Application:

The manufacturing process required an accurate measure of two different fluids into a day tank.  The blended materials, acrylamide (ACR) and glycerine (GLY) are then used in a subsequent process. Accuracy of measurement (+/-0.5%) was a critical requirement of the process and provided a cost savings.

Flow Meter Drawing:

pharmaceutical-application

 

Solution:

G Series Meters added to the individual lines send a signal (4-20 mA) back to the PLC. This signal at the PLC allows operators to monitor usage throughout the process.

Advantages of Using GPI Flow Meters:

  • Cost Savings
  • Self Contained
  • Compact Size
  • Accuracy

Comment Form

About this site

The Flow Meter Applications web site was created to inform individuals interested in learning more about how GPI flow meters are used across different industries. We hope you will continue to visit our web site regularly to read about the multiple ways GPI flow meters are helping individuals around the world.