<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>FlowMeterApplications.Com &#187; flow meter</title>
	<atom:link href="http://www.flowmeterapplications.com/tag/flow-meter/feed/" rel="self" type="application/rss+xml" />
	<link>http://www.flowmeterapplications.com</link>
	<description>Brought to you by: Great Plains Industries, Inc. (GPI)</description>
	<lastBuildDate>Fri, 14 Aug 2009 14:46:22 +0000</lastBuildDate>
	<generator>http://wordpress.org/?v=2.9.2</generator>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
			<item>
		<title>Water/Glycol Flow Meter Application</title>
		<link>http://www.flowmeterapplications.com/waterglycol-flow-meter-application/</link>
		<comments>http://www.flowmeterapplications.com/waterglycol-flow-meter-application/#comments</comments>
		<pubDate>Wed, 01 Jul 2009 15:13:16 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Flow Meter Application]]></category>
		<category><![CDATA[flow]]></category>
		<category><![CDATA[flow meter]]></category>
		<category><![CDATA[flow meters]]></category>
		<category><![CDATA[glycol]]></category>
		<category><![CDATA[gpi]]></category>
		<category><![CDATA[meter]]></category>
		<category><![CDATA[monitoring flow]]></category>
		<category><![CDATA[water]]></category>

		<guid isPermaLink="false">http://www.flowmeterapplications.com/?p=64</guid>
		<description><![CDATA[Company Type: Metro Airport
Market: Transportation Equipment
Application Category: Inventory Management
GPI Flow Meters Used: G2S20N09GMB with 113275-1
 
Problem:
The expensive deicing mixture was being wasted causing expenses to increase. Monitoring usage by individual treatment was required. Accurate billing receipts were important.

Flow Meter Application:
Vendor delivers various chemicals to end-users in multiple markets. The meter is installed between the pump [...]]]></description>
			<content:encoded><![CDATA[<h4>Company Type: Metro Airport</h4>
<h4>Market: Transportation Equipment</h4>
<h4>Application Category: Inventory Management</h4>
<h4>GPI Flow Meters Used: <a href="http://catalog.gpi.net/item/industrial-flowmeters/g2-industrial-meters-stainless-steel-2/pn-2144?&amp;plpver=10&amp;origin=keyword&amp;by=prod&amp;filter=0" target="_blank">G2S20N09GMB</a> with <a href="http://catalog.gpi.net/item/electronics-choices/accessories-4/fm-approved-remote-kit-assembly?&amp;plpver=10&amp;origin=keyword&amp;by=prod&amp;filter=0" target="_blank">113275-1</a></h4>
<p><span style="color: #0099cc;"> </span></p>
<h3>Problem:</h3>
<p>The expensive deicing mixture was being wasted causing expenses to increase. Monitoring usage by individual treatment was required. Accurate billing receipts were important.</p>
<p><span id="more-64"></span></p>
<h3>Flow Meter Application:</h3>
<p>Vendor delivers various chemicals to end-users in multiple markets. The meter is installed between the pump and hose reel to accurately measure and charge customers for the product delivered. Chemicals delivered range from detergents and deodorizers to caustics and acids. Accuracy of measurement was a critical requirement of this process.</p>
<h3>Flow Meter Drawing:</h3>
<p><a href="http://www.flowmeterapplications.com/wp-content/uploads/2009/07/airplane-application.jpg"><img class="aligncenter size-full wp-image-70" title="airplane-application" src="http://www.flowmeterapplications.com/wp-content/uploads/2009/07/airplane-application.jpg" alt="airplane-application" width="500" height="299" /></a></p>
<h3>Solution:</h3>
<p>The GPI G2S20N09GMB meter and condition signal output module reading in gallons sent a pulse out to a ticket printer. This provided an accurate billing receipt by usage. All equipment was contained within the truck and protected from tampering or elements.</p>
<h3>Advantages of Using GPI Flow Meters:</h3>
<ul>
<li>Cost Savings</li>
<li>Accuracy</li>
<li>Payback</li>
</ul>
<h4>Questions?</h4>
<p>If you have questions please feel free to leave a comment on this page or call GPI Customer Service at 888-996-3837 or 316-686-6746.  You can also visit the GPI web site at <a onclick="pageTracker._trackPageview('/outbound/article/http://www.gpimeters.net');" href="http://www.gpimeters.net/"><span style="color: #0099cc;">www.gpimeters.net</span></a>.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.flowmeterapplications.com/waterglycol-flow-meter-application/feed/</wfw:commentRss>
		<slash:comments>2</slash:comments>
		</item>
		<item>
		<title>Water Supply Flow Meter Application &#8211; Drinking Water Utility</title>
		<link>http://www.flowmeterapplications.com/water-supply-flow-meter-application-drinking-water-utility/</link>
		<comments>http://www.flowmeterapplications.com/water-supply-flow-meter-application-drinking-water-utility/#comments</comments>
		<pubDate>Tue, 21 Apr 2009 14:56:32 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Flow Meter Application]]></category>
		<category><![CDATA[drinking water flow meter]]></category>
		<category><![CDATA[flow meter]]></category>
		<category><![CDATA[monitoring ozone]]></category>
		<category><![CDATA[water supply flow meter]]></category>

		<guid isPermaLink="false">http://www.flowmeterapplications.com/?p=55</guid>
		<description><![CDATA[Company Type: Drinking Water Utility
Market: Water Supply
Application Category: Monitoring
GPI Flow Meters Used: G2P05N09GMA

Problem:
Opening the pipe to measure sample flow rate could expose technicians to toxic levels of ozone. Leaving valves wide open wastes large volumes of water. If the flowrate is to low or too high analyzer readings are not accurate.

Flow Meter Application:
At the end of [...]]]></description>
			<content:encoded><![CDATA[<h4>Company Type: Drinking Water Utility</h4>
<h4>Market: Water Supply</h4>
<h4>Application Category: Monitoring</h4>
<h4>GPI Flow Meters Used: <a href="http://catalog.gpi.net/item/industrial-meters/g2-industrial-meters-pvdf-2/pn-5199?&amp;plpver=10&amp;origin=keyword&amp;by=prod&amp;filter=0" target="_blank">G2P05N09GMA</a></h4>
<p><br/></p>
<h3>Problem:</h3>
<p>Opening the pipe to measure sample flow rate could expose technicians to toxic levels of ozone. Leaving valves wide open wastes large volumes of water. If the flowrate is to low or too high analyzer readings are not accurate.</p>
<p><span id="more-55"></span></p>
<h3>Flow Meter Application:</h3>
<p>At the end of the ozone chambers, there are instruments for measuring residual levels of ozone. These ozone analyzers require 1-5 GPM. The sample line runs to a closed waste line, in case there is a high level of ozone. Safety to technicians is a concern when working with ozone. Leaving valves wide open wastes too much water. Flowrate cannot be too low or too high and still expect accuracy in the analyzer reader. Rotameters had been used but failed due to turbidity levels and the float would stick.</p>
<h3>Flow Meter Drawing:</h3>
<p><a href="http://www.flowmeterapplications.com/wp-content/uploads/2009/04/ozone-application.jpg"><img class="aligncenter size-full wp-image-56" title="ozone-application" src="http://www.flowmeterapplications.com/wp-content/uploads/2009/04/ozone-application.jpg" alt="ozone-application" width="500" height="299" /></a></p>
<h3>Solution:</h3>
<p>G Series Meters added to the individual lines send a signal (4-20 mA) back to the PLC. This signal at the PLC allows operators to monitor usage throughout the process.</p>
<h3>Advantages of Using GPI Flow Meters:</h3>
<ul>
<li>Cost Savings</li>
<li>Safety</li>
<li>Compact Size</li>
<li>Accuracy</li>
<li>Easy to Install</li>
</ul>
<h4>Questions?</h4>
<p>If you have questions please feel free to leave a comment on this page or call GPI Customer Service at 888-996-3837 or 316-686-6746.  You can also visit the GPI web site at <a onclick="pageTracker._trackPageview('/outbound/article/http://www.gpimeters.net');" href="http://www.gpimeters.net/"><span style="color: #0099cc;">www.gpimeters.net</span></a>.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.flowmeterapplications.com/water-supply-flow-meter-application-drinking-water-utility/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Welcome to the Flow Meter Applications Web Site</title>
		<link>http://www.flowmeterapplications.com/flowmeters-welcome/</link>
		<comments>http://www.flowmeterapplications.com/flowmeters-welcome/#comments</comments>
		<pubDate>Thu, 26 Feb 2009 22:21:25 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[General Info]]></category>
		<category><![CDATA[flow meter]]></category>
		<category><![CDATA[flow meter applications]]></category>
		<category><![CDATA[flow meter manufacturer]]></category>
		<category><![CDATA[flow meter supplier]]></category>
		<category><![CDATA[flow meters]]></category>
		<category><![CDATA[gpi flow meters]]></category>

		<guid isPermaLink="false">http://www.flowmeterapplications.com/?p=1</guid>
		<description><![CDATA[The flow meter applications web site is brought to you by Great Plains Industries, Inc.  This web site is intented to show how GPI flow meters are used in different applications all around the world.  It is our hope that you will find the information on our site educational and enlightening.  For each application that is [...]]]></description>
			<content:encoded><![CDATA[<p>The flow meter applications web site is brought to you by <a href="http://www.gpimeters.net/" target="_blank">Great Plains Industries, Inc</a>.  This web site is intented to show how <a href="http://catalog.gpi.net/" target="_blank">GPI flow meters </a>are used in different applications all around the world.  It is our hope that you will find the information on our site educational and enlightening.  For each application that is featured we will highlight a problem and give a solution to that problem.  We will also give you some insight as to what GPI flow meters were used with that certain application.</p>
<p>This site will also serve as a sound board for questions you might have about these applications and flow meters.  Thanks again for taking the time to visit us and please keep coming back as we release new information on how these flow meters can help you with one of your current applications.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.flowmeterapplications.com/flowmeters-welcome/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>
